MIL,STD-461 Tests

Why is the MIL-STD-461 Test is Necessary

Ege Test Center and MIL-STD-461 Testing

The MIL-STD-461 standard, which we test as the Ege Test Center, is required for the activities of the Ministry of Defense (DoD) and the requirements for the control of electromagnetic interference (EMI) emissions and sensitivity characteristics of electronic, electrical and electromechanical equipment and subsystems designed or supplied for use by their agents. The MIL-STD-461 standard is the basic standard for military electromagnetic compatibility testing at the device and subsystem level.

Measurement Forms;

Dissemination through conductivity (CE-Conducted Emission)
Susceptibility through conductivity (CS-Conducted Susceptibility):
Since the MIL-STD-461 is developed for use on all platforms and different platforms have different needs, all tests specified in the standard are not applied to all platforms.

For example;

Test CodeDescription
CE101Conductivity Transduction, Power Lines, 30 Hz – 10 kHz
CE102Conductivity Transduction, Power Lines, 10 kHz – 10 MHz
CE106Conductivity Transmission, Antenna Terminal, 10 kHz – 40 GHz
CS101Conductivity Throughput, Power Lines, 30 Hz to 150 kHz
CS103Sensitivity through Conductivity, Antenna Input, Intermodulation, 15 kHz – 10 GHz
CS104Sensitivity through conductivity, antenna input, suppression of unwanted signals, 30 Hz – 20 GHz
CS105Sensitivity through Conductivity, Antenna Input, Cross-Modulation, 30 Hz – 20 GHz
CS106Conductivity through Transition, Transitions, Power Lines
CS109Sensitivity through conductivity, construction current, 60 Hz – 100 kHz
CS11414 Conductivity through Cable Conductivity, Cable Injection, 10 kHz to 200 MHz
CS115Sensitivity through Conductivity, Cable Injection, Impact
CS116Sensitivity through conductivity, suppressed sinusoidal transitions, cables and power lines, 10 kHz to 100 MHz
RE101Radiation Transmission, Magnetic Field, 30 Hz – 100 kHz
RE102Radiation Transmission, Electric Field, 10 kHz – 18 GHz
RE103Radiation Transmission, Antenna Harmonic Outputs, 10 kHz – 40 GHz
RS101Fluorescence Through Radiation, Magnetic Field, 30 Hz – 100 kHz
RS103Fluorescence Through Radiation, Electric Field, 2 MHz – 40 GHz
RS105Temporality through Radiation, Temporary Electromagnetic Field

For example, the CE101 test is applied to the devices to be used in aircraft, submarine and ground forces,
but not to the devices to be used in aircraft connected to air forces. The CE102 test, on the other hand, is a test for all platforms. Although the standard on which the test is to
be applied to which platforms are defined, the conditions specified in the standard may not be met or the tests not required by the standard may be requested by the customer and the testing needs are only hard to follow from the standard. Therefore, starting from the start of the project test planning and preparation of a Test Plan document is very useful.

Why the MIL-STD-461 Test is necessary?

Thanks to the knowledge and experience of the Egetest Center expert teams for MIL-STD-461, you will be able to sell your product to the European market without any problem. For detailed information and communication, you can mail to marketing@egetestcenter.com or by entering the https://en.egetestcenter.com/applyonline/ and You can fill form.